VT DSO-2810H (Legacy Product)

VT-DSO-2810H
VT DSO-2810H (US$259.95)

PC based USB 8-Bit 100MSPS 40MHz Oscilloscope, Spectrum Analyzer, Signal Generator*
*Signal Generator function is available via the sound card or other DAC device, rather than the VT DSO-2810H unit
Find out more: Manual

Package Contents

  1. VT DSO-2810H unit with a hardware activated Multi-Instrument Standard Software License
  2. 2 x 60MHz Oscilloscope Probe PP-80 with two switchable positions: x 1, x 10
  3. USB cable (1.05 m)
  4. CD (contains the copy-protected Multi-Instrument Software and VT DSO-2810H driver)

Hardware Specifications

General
Sampling Frequency 1. Single Channel, Maximum 60000 Samples*
100MHz, 50MHz, 20MHz, 10MHz, 5MHz, 2MHz, 1MHz, 500kHz, 200kHz, 100kHz, 50kHz, 20kHz, 10kHz

2. Single or Dual Channels, Maximum 30000 Samples per Channel
50MHz, 25MHz, 10MHz, 5MHz, 2.5MHz, 1MHz, 500kHz, 250kHz, 100kHz, 50kHz, 25kHz, 10kHz, 5kHz

3. Single or Dual Channels, Maximum 10000 Samples per Channel
2.5kHz

4. Single or Dual Channels, Maximum 500 Samples per Channel, work in Roll Mode**
50Hz, 25Hz, 5Hz
Analog Bandwidth 40MHz
Number of Input Channels 2
ADC Bit Resolution 8 Bits
Input Voltage Range ± 40mV, ± 80mV, ± 200mV, ± 400mV, ± 800mV, ± 2V, ± 4V, ± 8V, ± 20V
Maximum Allowed Input Voltage ± 35V
DC Accuracy ± 3%
Coupling Type AC/DC
Input Isolation No
Terminal Type Referenced Single-Ended
Buffer Size 30000 bytes per Channel
Sweep Time 600µs~100s (with buffer fully filled)
Trigger Source CH1, CH2, EXT, ALT
Trigger Level Adjustable
EXT Trigger Level Adjustable in the range of -4V ~ 4V
Trigger Edge Rising, Falling
Trigger Mode Auto, Normal, Single
Pre-Trigger 0 ~ -100%
Input Impedance 1 MΩ , 25 pF
Output Signal for Probe Calibration 2Vpp, 1kHz, Square Wave
Streaming Supported No
Interface USB
Casing Internally shielded plastic
Device Category in Multi-Instrument VT DSO H1
Power Bus powered by USB port, no external power source required
Power Consumption Max. 2.5W
Dimensions 203 mm (L) x 99 mm (W) x 33 mm (H)
System Requirement Windows XP, Vista, 7, 8, 8.1, 10 or 11, 32 bit or 64 bit

*Some of these frequencies are not listed in the sampling frequency selection combo box of the Multi-Instrument software. You need to stop the oscilloscope, enter the sampling frequency value directly into that combo box and then set the number of sampling channels to single, if you need to use these sampling frequencies.
**Under these sampling frequencies, adjusting the trigger mode, trigger source, trigger edge, trigger level, trigger delay will have no impact on the sampling.

Hardware Specifications (PP-80 Oscilloscope Probe)

General
Attenuation Ratio x 1, x 10
Bandwidth (-3dB) DC ~ 60 MHz (x 10), DC ~ 6 MHz (x 1)
Input Impedance 10 MΩ (x 10, with VT DSO-2810H connected)
1 MΩ (x 1, with VT DSO-2810H connected)
Input Capacitance 18.5 pF~22.5 pF (x 10), 85 pF~ 115 pF (x 1)
Input Capacitance Compensation Range 15 ~ 40 pF
Length 1.2 m

Accessories include: a 6" snap-on rotating ground lead, a sprung hook, two marker rings, a probe compensation adjustment tool, two probe tip caps.